Description
Calculate supplied normalized intensity deviation and its square.
Atmospheric scalar terms require explicit averaging, spectral, geometric and propagation conventions. One fluctuation product is not a time-averaged flux, a squared deviation is not a full scintillation index, and a Nyquist interval does not de-alias radar velocity. Layer terms require compatible units and model assumptions.
Calculate supplied normalized intensity deviation and its square.
When to use this tool
Use Scintillation Normalized Intensity Deviation when you already have intensity, meanIntensity and need to calculate supplied normalized intensity deviation and its square.
How to use the tool and how it works
- Enter intensity, meanIntensity. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read normalizedDeviation, squaredDeviation. Use the output convention below.
Require intensity>=0 and meanIntensity>0; deviation=(intensity-mean)/mean and square it.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| intensity | Intensity | Required. Finite number; minimum 0. |
| meanIntensity | Mean Intensity | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| normalizedDeviation | Normalized Deviation | Required. Finite number. |
| squaredDeviation | Squared Deviation | Required. Finite number. |
{
"input": {
"intensity": 12,
"meanIntensity": 10
},
"output": {
"normalizedDeviation": 0.2,
"squaredDeviation": 0.04000000000000001
}
} Limitations and assumptions
- The mean is supplied. One squared deviation is not the scintillation index without the appropriate ensemble or time average, calibration and model.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use the complete measurement and physical retrieval model. Include calibration, averaging, source geometry, spectral response and relevant transfer or flow effects when local weights and signal factors cannot establish the desired atmospheric quantity.
References
Similar or alternative tools
- Refractivity Dry Wet Component Pair
Combine supplied dry/wet refractivity components and a wet share.
- Radiometer Dark Current Subtraction Term
Subtract a supplied radiometer dark signal.