Description
Return separately normalized sample/blank concentration and uncertainty.
Standard uncertainties combine through the measurement model and the covariance of its inputs. Correlated errors may reinforce or cancel, and treating a scale or volume as exact is a substantive assumption. A propagated value is different from a complete uncertainty budget or a statistical decision.
Return separately normalized sample/blank concentration and uncertainty.
When to use this tool
Use Atmospheric Blank Subtraction Uncertainty Term when checking the stated uncertainty-propagation term under supplied correlation and exact-input assumptions.
How to use the tool and how it works
- Enter sampleAmount, blankAmount, sampleVolume, blankEquivalentVolume, sampleUncertainty, blankUncertainty. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read correctedConcentration, combinedUncertainty. Use the output convention below.
Return separately normalized sample/blank concentration and uncertainty. Require positive sample/blank-equivalent volumes and nonnegative amount uncertainties; corrected = sampleAmount/sampleVolume-blankAmount/blankVolume, combined uncertainty is hypot(uSample/sampleVolume,uBlank/blankVolume).1
Uncertainty propagation depends on the measurement model and input covariance. Omitting correlations or treating volume as exact requires justification; this helper is only one specified contribution.2
| Input field | Meaning and units | Accepted input |
|---|---|---|
| sampleAmount | Sample Amount | Required. Finite number. |
| blankAmount | Blank Amount | Required. Finite number. |
| sampleVolume | Sample Volume | Required. Finite number; strictly above 0. |
| blankEquivalentVolume | Blank Equivalent Volume | Required. Finite number; strictly above 0. |
| sampleUncertainty | Standard uncertainty of sampleAmount, not of concentration or sampled volume. | Required. Finite number; minimum 0. |
| blankUncertainty | Standard uncertainty of blankAmount; treated independent of sample uncertainty. | Required. Finite number; minimum 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| correctedConcentration | Corrected Concentration | Required. Finite number. |
| combinedUncertainty | Combined Uncertainty | Required. Finite number. |
{
"input": {
"sampleAmount": 10,
"blankAmount": 2,
"sampleVolume": 2,
"blankEquivalentVolume": 2,
"sampleUncertainty": 0.6,
"blankUncertainty": 0.8
},
"output": {
"correctedConcentration": 4,
"combinedUncertainty": 0.5
}
} Limitations and assumptions
- This assumes independent amount uncertainties and exact volumes; correlations, volume uncertainty and a complete analytical uncertainty budget are omitted.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Construct a justified measurement model and complete uncertainty budget, including correlations, calibration and omitted scale/volume terms, for reliable uncertainty reporting.
References
Similar or alternative tools
- Biomonitoring Lablot Reference Uncertainty
Return a paired-lot difference and correlated uncertainty ratio.
- Aliquot Volume Uncertainty Term
Return equal-uncertainty correlated dispense uncertainty.