Occultation Step Candidates
Find discrete sampled flux-drop candidates at a supplied threshold; two steps are not by themselves evidence for an occulted binary.
Description
A sampled fractional flux drop can nominate an occultation step.
A sampled fractional flux drop can nominate an occultation step. Its time is the later sample's time, so cadence limits timing precision and two candidates alone do not establish a binary source.1
Find discrete sampled flux-drop candidates at a supplied threshold; two steps are not by themselves evidence for an occulted binary.
When to use Occultation Step Candidates
Use this tool to find discrete sampled flux-drop candidates at a supplied threshold; two steps are not by themselves evidence for an occulted binary.
Prepare the source, detector or coordinate measurements. Confirm frame, epoch, angular units, axis directions and the stated RA proper-motion convention before entering values.
How to use Occultation Step Candidates and understand its results
- Prepare the source, detector or coordinate measurements. Confirm frame, epoch, angular units, axis directions and the stated RA proper-motion convention before entering values.
- Enter sampleTimesSeconds, fluxes, minimumFractionalDrop using the field table and calculation rules, then run the tool.
- Read stepTimesSeconds, stepCount, twoStepCandidate. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| sampleTimesSeconds | Sample times seconds | list of number | Required |
| fluxes | Fluxes | list of number | Required |
| minimumFractionalDrop | Minimum fractional drop | number | Required |
Enter aligned nonempty increasing times in seconds and strictly positive fluxes, plus a drop threshold in (0,1]. The tool checks adjacent samples, returns qualifying later-sample times and their count, and sets twoStepCandidate only for exactly two candidates. No candidates is a successful outcome.
Paired lists must be nonempty and have equal lengths. Sequences checked for increasing order must be nonempty and strictly increasing; additional calculation rules may require more samples.
drop_i=(flux_(i−1)−flux_i)/flux_(i−1); candidate if drop_i≥threshold Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| stepTimesSeconds | Step times seconds | list of number |
| stepCount | Step count | number |
| twoStepCandidate | Two step candidate | boolean |
{
"input": {
"sampleTimesSeconds": [
0,
1,
2,
3,
4
],
"fluxes": [
100,
100,
70,
70,
40
],
"minimumFractionalDrop": 0.2
},
"output": {
"stepTimesSeconds": [
2,
4
],
"stepCount": 2,
"twoStepCandidate": true
}
} Limitations and assumptions
No denoising, significance calculation, event interpolation or occultation model is applied. Zero flux is an input error in this implementation, and instrumental/noise steps can also qualify.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use Occultation Stellar Angular Diameter: Estimate diameter from a central occultation-edge crossing and shadow speed, then angular size; diffraction, integration smearing and noncentral chords are excluded. For a complementary task, use Iterative Astrometric Sigma Clip: Iteratively clip residuals using recalculated sample standard deviation, retaining original indices and a bounded iteration count.
References
-
Occultation Step Candidates — tool.io
Similar or alternative tools
- Occultation Stellar Angular Diameter
Estimate diameter from a central occultation-edge crossing and shadow speed, then angular size; diffraction, integration smearing and noncentral chords are excluded.
- Iterative Astrometric Sigma Clip
Iteratively clip residuals using recalculated sample standard deviation, retaining original indices and a bounded iteration count.