Skip to content

Main content

Plankton Flowmeter Slip Factor Tool

Calculate plankton flowmeter slip factor from explicit caller-supplied inputs.

Loading tool…

Description

Return flowmeter-slip-adjusted tow distance and volume.

Aquatic sampling expands observed counts using supplied area, filtered volume or processed fractions. Net efficiency, slip and grain-class boundaries affect that accounting. A scaled count or one-point class assignment does not establish true population abundance, detection probability or a universal substrate classification.

Return flowmeter-slip-adjusted tow distance and volume.

When to use this tool

Use Plankton Flowmeter Slip Factor when checking the stated aquatic sampling-volume, density or class-boundary convention.

How to use the tool and how it works

  1. Enter revolutions, distancePerRevolution, suppliedSlip, mouthArea. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read distance, filteredVolume. Use the output convention below.

Return flowmeter-slip-adjusted tow distance and volume. Require nonnegative revolutions, distancePerRevolution, mouthArea and slip in [0,1]; distance = revolutions*calibration*(1-slip), volume = distance*area.1

Input fieldMeaning and unitsAccepted input
revolutionsRevolutionsRequired. Finite number; minimum 0.
distancePerRevolutionDistance Per RevolutionRequired. Finite number; minimum 0.
suppliedSlipLost fraction of ideal distance; retained travel multiplies by 1-suppliedSlip.Required. Finite number; minimum 0; maximum 1.
mouthAreaMouth AreaRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
distanceDistanceRequired. Finite number.
filteredVolumeFiltered VolumeRequired. Finite number.
json
{
  "input": {
    "revolutions": 100,
    "distancePerRevolution": 0.1,
    "suppliedSlip": 0.2,
    "mouthArea": 0.5
  },
  "output": {
    "distance": 8,
    "filteredVolume": 4
  }
}

Limitations and assumptions

  • Slip is the lost fraction under this convention; no actual instrument calibration, net capture or survey validity is verified.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified field methods, calibrated sampling efficiency and an appropriate statistical or classification scheme for abundance and ecological assessment.

References

  1. Calculation and input contract: aquatic-science/plankton-flowmeter-slip-factor — tool.io

Similar or alternative tools