Roughness 70 Hz Reference

Return the documented 70 Hz maximum of the 1-asp roughness reference while distinguishing that demonstration from a universal prediction.

Description

Roughness reference stimuli tie perceptual units to specified carrier, level and modulation conditions.

Roughness reference stimuli tie perceptual units to specified carrier, level and modulation conditions. A nominal reference peak is not universal.1

Return the documented 70 Hz maximum of the 1-asp roughness reference while distinguishing that demonstration from a universal prediction.

When to use Roughness 70 Hz Reference

Use this tool to return the documented 70 Hz maximum of the 1-asp roughness reference while distinguishing that demonstration from a universal prediction.

Choose a supported reference topic, run an input-free reference with an empty object, or prepare the measured values and caller-supplied test records requested. Keep acoustic metrics, frequency, units and test conditions consistent.

How to use Roughness 70 Hz Reference and understand its results

  1. Choose a supported reference topic, run an input-free reference with an empty object, or prepare the measured values and caller-supplied test records requested. Keep acoustic metrics, frequency, units and test conditions consistent.
  2. Run the reference with an empty object {}. No input values or topic selection are required.
  3. Read asperCarrierHertz, asperLevelDecibels, asperModulationDepth, evidenceScope, peakModulationHertz, reference, universalPeak. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
(none)Run the reference with an empty object {}.No values requiredNot applicable

Run with an empty object. Return the fixed 1-asp reference parameters, evidence scope, bibliographic reference and universalPeak=false.

reference: carrier=1000Hz, level=60dB, depth=1, modulation=70Hz

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
asperCarrierHertz1-asp carrier frequency (Hz)number
asperLevelDecibels1-asp level (dB SPL)number
asperModulationDepth1-asp modulation depthnumber
evidenceScopeEvidence scopestring
peakModulationHertzReference peak modulation frequency (Hz)number
referenceReferencestring
universalPeakUniversal peakboolean
json
{
  "input": {},
  "output": {
    "asperCarrierHertz": 1000,
    "asperLevelDecibels": 60,
    "asperModulationDepth": 1,
    "evidenceScope": "The 70 Hz value is the modulation rate in the 1-asp reference stimulus and a near-maximum reported for some fully modulated high-carrier tones. It is not a universal roughness peak across carriers, modulation depth, spectra, levels, listeners, or procedures.",
    "peakModulationHertz": 70,
    "reference": "Fastl and Zwicker, Psychoacoustics: Facts and Models (2007), roughness definition and discussion.",
    "universalPeak": false
  }
}

Limitations and assumptions

No signal, roughness calculation or listener measurement is provided. Carrier/spectrum/level and procedure can change observed maxima.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Acoustic Sharpness Reference: Return the definition, unit, reference sound, and interpretation cautions for psychoacoustic sharpness. For a complementary task, use One-Decibel JND Reference: Return the nominal 1 dB level-difference reference with the psychophysical conditions required before it can be called a just-noticeable difference.

References

  1. Roughness 70 Hz Reference — tool.io

Similar or alternative tools

  • Acoustic Sharpness Reference

    Return the definition, unit, reference sound, and interpretation cautions for psychoacoustic sharpness.

  • One-Decibel JND Reference

    Return the nominal 1 dB level-difference reference with the psychophysical conditions required before it can be called a just-noticeable difference.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies