Spectral Ratio Two Station Q Estimate Calculator
Two-station coda Q from the log spectral-ratio slope: ln(A₁/A₂) = −π f Δt / Q.
Description
Two-station coda Q from the log spectral-ratio slope: ln(A₁/A₂) = −π f Δt / Q.
Spectral Ratio Two Station Q Estimate Calculator is a focused tool for the following task. Two-station coda Q from the log spectral-ratio slope: ln(A₁/A₂) = −π f Δt / Q. It reports Q_c, Valid? from the values you provide rather than inventing measurements, coefficients, or professional judgment that are not part of the input.
When to use Spectral Ratio Two Station Q Estimate
Use this seismology calculation to reproduce a stated convention, screen observations, or compare scenarios whose units, coordinate conventions, catalog selection, and model assumptions are known.
- m (1/Hz)
- Required number in 1/Hz. Slope of ln(A₁/A₂) versus frequency.
- Δt (s)
- Required number in s. Lapse-time difference between stations.
The cited overview of Seismometer supplies background for the terminology and domain context used by this tool.1
How Spectral Ratio Two Station Q Estimate works
Two-station coda Q from the log spectral-ratio slope: ln(A₁/A₂) = −π f Δt / Q. Inputs are interpreted exactly in the displayed units and the calculation returns the following fields without presentation rounding.
- Q_c
- Returned number. Estimated coda quality factor.
- Valid?
- Returned boolean. Whether the slope has the attenuation sign.
Limitations and assumptions
- Earth structure, source geometry, path effects, site response, instrument response, catalog completeness, uncertainty, and the fitted range can dominate the accuracy of simplified seismic calculations.
- Δt must be at least 0.
- Use finite inputs in the displayed units, preserve source measurements and assumptions, and independently verify consequential decisions.
Alternative or Complementary approaches
For analysis or hazard decisions, retain uncertainty and provenance and compare the result with waveform processing, calibrated regional models, and guidance from qualified seismologists or the responsible agency.
References
-
Seismometer — Wikipedia contributors
Similar or alternative tools
- Wadati Origin Time Single Station Formula Calculator
Origin-time estimate from one station using the Wadati ratio: t₀ = (R·t_p − t_s)/(R − 1).
- Coda Duration Magnitude Nuttli Formula Calculator
Nuttli-style coda-duration magnitude M_d = a + b·log₁₀(τ) + c·Δ with regional coefficients.
- Damping Response Spectrum Heuristic Scaling
Heuristic spectral scaling from 5% to another damping ratio: F = (0.05/ζ)^0.25.