Housner Spectral Intensity Calculator
SI(Housner) = integral of PSV over 0.1–2.5 s approximated by trapezoid over supplied spectral velocities.
Description
SI(Housner) = integral of PSV over 0.1–2.5 s approximated by trapezoid over supplied spectral velocities.
Housner Spectral Intensity Calculator is a focused tool for the following task. SI(Housner) = integral of PSV over 0.1–2.5 s approximated by trapezoid over supplied spectral velocities. It reports SI from the values you provide rather than inventing measurements, coefficients, or professional judgment that are not part of the input.
When to use Housner Spectral Intensity
Use this seismology calculation to reproduce a stated convention, screen observations, or compare scenarios whose units, coordinate conventions, catalog selection, and model assumptions are known.
- PSV_i
- Required list. Pseudo-spectral velocity samples (cm/s).
- ΔT (s)
- Required number in s. Period spacing.
The cited overview of Seismic intensity scales supplies background for the terminology and domain context used by this tool.1
How Housner Spectral Intensity works
SI(Housner) = integral of PSV over 0.1–2.5 s approximated by trapezoid over supplied spectral velocities. Inputs are interpreted exactly in the displayed units and the calculation returns the following fields without presentation rounding.
- SI (cm)
- Returned number in cm. Housner spectral intensity.
Limitations and assumptions
- Earth structure, source geometry, path effects, site response, instrument response, catalog completeness, uncertainty, and the fitted range can dominate the accuracy of simplified seismic calculations.
- ΔT must be at least 0.
- Use finite inputs in the displayed units, preserve source measurements and assumptions, and independently verify consequential decisions.
Alternative or Complementary approaches
For analysis or hazard decisions, retain uncertainty and provenance and compare the result with waveform processing, calibrated regional models, and guidance from qualified seismologists or the responsible agency.
References
-
Seismic intensity scales — Wikipedia contributors
Similar or alternative tools
- Arias Intensity Duration Proxy Calculator
Arias intensity proxy I_a ≈ (π/2g)·∫a² dt approximated by PGA² times effective duration.
- Average Moment Rate From Moment Duration Calculator
Average seismic moment release rate over a specified source duration: Ṁ₀ = M₀/T.
- Average Radiation Factor Boore Boatwright Lookup
Boore-Boatwright style average radiation factors for P and S waves over the focal sphere.