Raman Stokes Cascade Wavelengths
Compute silica-fiber Raman Stokes wavelengths from a pump wavelength and integer cascade order using the 440 cm^-1 shift.
Description
Compute silica-fiber Raman Stokes wavelengths from a pump wavelength and integer cascade order using the 440 cm^-1 shift.
Raman Stokes Cascade Wavelengths: Compute silica-fiber Raman Stokes wavelengths from a pump wavelength and integer cascade order using the 440 cm^-1 shift.
When to use Raman Stokes Cascade Wavelengths
Use this laser calculation or lookup for a first-pass optics, pulse, beam, gain-medium, diode, fiber, or safety comparison under explicitly stated wavelength and operating conditions.
- Pump wavelength (nm)
- Pump wavelength launching the cascade.
- Stokes order
- Stokes order n = 1, 2, … (each step adds one 440 cm^-1 shift).
How Raman Stokes Cascade Wavelengths works
Compute silica-fiber Raman Stokes wavelengths from a pump wavelength and integer cascade order using the 440 cm^-1 shift. The tool evaluates the supplied inputs together and returns the named outputs below; it does not infer omitted operating conditions or change the units shown.1
- Stokes wavelength (nm)
- Wavelength of the selected Stokes order.
- Shift per order (cm^-1)
- Raman shift applied per order.
Limitations and assumptions
- Laser behavior depends on wavelength, mode, coherence, pulse shape, beam quality, cavity and optical losses, material data, temperature, alignment, nonlinear effects, damage thresholds, and measurement definitions. Lookup values are not substitutes for current device data or laser-safety analysis.
- Use finite inputs in the displayed units and preserve more precision than the final presentation requires. Independently verify safety-critical, financial, compliance, or production decisions.
Alternative or Complementary approaches
Verify constants and limits with primary literature and manufacturer data, propagate tolerances, model the complete optical train, and apply the relevant laser safety standard.
References
-
Fiber laser — Wikipedia contributors
Similar or alternative tools
- FBG Strain-Temperature Shift
Compute fiber Bragg grating wavelength shift from axial strain and temperature change using the silica photoelastic and thermo-optic coefficients.
- CO2 Line Selection Table
Look up common regular-isotope CO2 laser line wavelengths with band and isotopologue labels.
- Thulium/Holmium Water Absorption Lookup
Compare nominal 1908 nm thulium-fiber and 2090 nm holmium:YAG sources using tabulated water absorption and the corresponding 1/µa penetration estimate.